ETCR Meter Indonesia

Leakage Protector(RCD) Tester

EM8620/EM8640/EM8650/EM8650A Leakage Protector(RCD) Tester

EM8620 Leakage Protector(RCD) Tester
EM8640 Leakage Protector(RCD) Tester
EM8650 Leakage Protector(RCD) Tester
EM8650 Leakage Protector(RCD) Tester
EM8650 Leakage Protector(RCD) Tester

 

Product Series : Leakage Protector(RCD) Tester

Main Features :

Test the leakage action time, leakage action current value and line AC voltage of various leakage protection devices.
Output Test Current: 3mA ~ 1000mA (20 gears)
Leakage Current Operation Time Range: 0.001 ~ 1.000s
Leakage Operating Current Value Range: 3mA ~ 110mA (step mode)
Voltage Range: AC 0V ~ 600V
Rated Voltage: AC 220V
Measurement Mode: Manual or automatic
Phase Selection: 0° or 180°
Frequency Display: 50Hz/60Hz
Power Supply: Lithium battery, DC 7.4V, 2600mAh
Data Storage: 1000 groups.

Product Introduction

 

EM8650 Leakage Protector(RCD) Tester is specifically designed for on-site testing of the leakage action time, leakage action current value and line AC voltage of various leakage protection devices. The test current is divided into twenty ranges from 3 to 1000mA (3, 5, 7, 10, 15, 20, 25, 30, 35, 40, 50, 60, 100, 150, 200, 250, 300, 500, 600, 1000), and the leakage action time range is from 0.001s to 1.000s. The leakage operating current value is measured in a step mode, with a step value of 1mA or 5mA, and the range is: 3mA to 33mA. 10mA to 110mA.
EM8650 Leakage Protector(RCD) Tester adopts a 5-inch full-color touch screen, featuring battery power display, automatic shutdown after 5 minutes, indication of set fault voltage, backlight brightness adjustment, clock display, data storage and other functions. The display screen is equipped with a wiring guidance diagram to prompt operation methods. The instrument also has Bluetooth communication and USB communication functions. It is an ideal tool for on-site or indoor detection of various leakage protection devices.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.

Product Features
1. Manual and automatic measurement modes; Output test current: 3mA~1000mA.
2. Leakage Current Operation Time Range: 0.001 ~ 1.000s
3. Step Mode for leakage operating current value range: 3mA~110mA.
4. Data Storage: 1000 groups.
5. Bluetooth communication: View test data on mobile phone via APP.
6. USB communication: Download stored data to PC via host software.
  

Test Interface
  

Technical Parameters

Specification NameParameters Description
FunctionTest leakage current operation time, leakage operating current and AC line voltage of various RCDs
Power SupplyDC 7.4V 2600mAh rechargeable lithium battery
Display Mode5-inch color touch screen
Test ModeManual or automatic
Rated VoltageAC 220V/380V
Output Current Gears

Auto Mode:
3mA, 5mA, 7mA, 10mA, 15mA, 20mA, 25mA, 30mA, 35mA, 40mA, 50mA, 60mA, 100mA, 150mA, 200mA, 250mA, 300mA, 500mA, 600mA, 1000mA

Manual Mode:
X1/2: 5mA, 10mA, 15mA, 50mA, 150mA, 250mA
X1: 10mA, 20mA, 30mA, 100mA, 300mA, 500mA
X2: 20mA, 40mA, 60mA, 200mA, 600mA, 1000mA

Output Current Accuracy±10%rdg±5dgt
Leakage Current Operation Time RangeRange: 0.001s~1.000s; Resolution: 0.001s; Accuracy: ±5%rdg±3dgt
Leakage Operating Current Value Range

3mA~33mA; Resolution 1mA; Accuracy ±2dgt
10mA~110mA; Resolution 5mA; Accuracy ±2dgt

Voltage MeasurementRange: AC 0~600V; Resolution: 1V; Accuracy: ±2%rdg±5dgt
Frequency Display50Hz/60Hz
Phase Selection0° or 180°
Data Storage1000 groups of data with date/time auto-saved after test
Fault Indication

The LCD shows a “999” timeout indication, which may indicate that the rated operating current range being tested is too small or there is a Fault in the leakage protection device.
The LCD shows a “FAULT” overvoltage indication, which may indicate that the voltage of the connected line being tested exceeds 250V or there is component damage inside the instrument

Battery VoltageLow battery prompt at 7.0V, remind charging
Operating Current350mA (standby); 450mA Max (testing)
Bluetooth CommunicationView test data on mobile phone via APP
USB CommunicationDownload stored data to PC via host software
Dimensions212mm×175mm×85mm
WeightHost: approx. 944g (with battery); Total: approx. 2kg (with accessories)
Working Temperature & Humidity-10℃~40℃; ≤80%RH
Storage Temperature & Humidity-10℃~60℃; ≤70%RH
Insulation Withstand Voltage≥100MΩ, AC 2kV/rms (between housing and screws)
Safety StandardsIEC1010-1, IEC1010-2-032, Pollution Degree 2, CAT III (600V), IEC61326 (EMC)

Model Comparison

Product ModelTest CurrentLeakage Current Operate Time RangeVoltage RangeOthers

EM8620
15mA~1000mA, 12 levels0.001~1.000s—/

EM8640
5mA~1000mA, 15 levels0.001~1.000sAC 0V~600V

Step Test Mode

EM8650
3mA~1000mA, 20 levels0.001~1.000sAC  0V~600V

Step Test Mode

EM8650A
5mA ~ 1000mA, 16 levels0ms ~ 999msAC  0V~600V

Step Test Mode

Exit mobile version