EM8610A/EM8610 Socket Type Leakage Protector Tester

EM8610 Leakage Protector(RCD) Tester
Product Series : Socket Type Leakage Protector Tester
Main Features :
Used to test the leakage action time of various leakage protectors
Test Current: 10 ~ 35mA (6 gears)
Leakage Current Action Time Range: 0.001 ~ 1.000s
Rated Voltage: AC 220V
Product Introduction
EM8610 Leakage Protector(RCD) Tester is designed for on-site inspection of the working status of three-pole sockets and testing the leakage action time of leakage protectors. The test current is divided into 6 levels from 10 ~ 35mA (10mA, 15mA, 20mA, 25mA, 30mA, 35mA), and the test leakage current action time range is 0.001s ~ 1.000s. During the test, insert the three-pole plug of the instrument into the three-pole socket. The indicator lights A, B, and C of the instrument show the working status of the socket and whether the wiring is correct, and test the leakage current action time. The instrument is portable, small in size, light in weight, exquisite in appearance, and easy to carry. It is an ideal tool for on-site or indoor testing of various leakage protectors.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.
Product Features
1. The test current is divided into 6 levels from 10 ~ 35mA (10mA, 15mA, 20mA, 25mA, 30mA, 35mA).
2. The test leakage current action time range is 0.001s ~ 1.000s.
3. The instrument has high precision, light and exquisite size, easy to carry, and is especially suitable for on-site detection of leakage protectors.
Technical Parameters
| Specification Name | Parameters Description |
| Function | Inspect socket status and test RCD tripping time |
| Power Supply | DC9V, 6LR61 9V alkaline battery |
| Display Mode | 4-digit LCD with backlight |
| LCD Size | 35mm × 21.5mm; Display area: 32mm × 15mm |
| Rated Voltage | AC 220V (between tester terminals during RCD test) |
Leakage Current Gears | 10mA, 15mA, 20mA, 25mA, 30mA, 35mA |
| Leakage Initiating Time Range | 0.001s~1.000s |
| Leakage Initiating Time Display Accuracy | ± 5%rdg±3dgt |
| Gear Current Accuracy | ± 10%rdg+2dgt |
| ABC Indicators | Socket status indicators |
| TESTING Indicator | Flashes during testing |
| Battery Voltage | When the battery power is insufficient, a low battery voltage symbol is displayed to remind you to replace the battery |
| Working Current | Standby: 6mA Max; Test: 40mA Max |
| Dimensions | 140mm × 70mm × 50mm |
| Weight | Approx. 300g (with battery); |
| Working Temperature & Humidity | – 10℃~40℃; ≤80%RH |
| Storage Temperature & Humidity | – 10℃~60℃; ≤70%RH |
| Insulation Withstand Voltage | ≥100MΩ, AC 2kV/rms (between housing and screws) |
| Standards | IEC1010-1, IEC1010-2-032, Pollution Degree 2, CAT III (600V), IEC61326 (EMC) |
Model Comparison
| Product Model | Test Current | RCD Voltage | Zero-flame Voltage Measurement Range (L-N) | Zero-ground Voltage Measurement Range (N-E) |
| —— | AC 220V | 30V~250V/(50~60Hz) | 0.1V~10V/(50-60Hz) | |
| 10~35mA(6 gears) | —— | —— | —— |