ETCR Meter Indonesia

Wireless HV/LV Remote Phase Detector

EM1050/EM1500/EM1600/EM1500A/EM1500B/EM1560A Wireless HV/LV Remote Phase Detector

EM1050 Wireless High Voltage Phase Sequence Detector
EM1500 Wireless High Voltage Phase Detector
EM1600 Wireless High Voltage Phase Detector
EM1500A Remote Wireless High Voltage Phase Detector
EM1500B Satellite Timing Service Remote High Voltage Phase Detector
EM1560A Multifunction Statellite Remote Wireless Phase Detector
EM1500A Remote Wireless High Voltage Phase Detector

 

Product Series : Wireless HV/LV Remote Phase Detector

Main Features :

Used for remote nuclear phase, phase test, frequency test, phase sequence judgment and power inspection of power lines, high-voltage switchgear or substations below 500kV
Nuclear Phase Voltage: 10V~500kV
Remote core-to-core Distance: 5000m
Ordinary core-to-core Distance: 200m
Phase Range: 0°~360°
Frequency Range: 45.0Hz~65.0Hz
Voltage Level Display Range:0.4kV ~ 110kV
Length Of Telescopic Insulating Rod:670mm ~ 3000mm
Date Storages: 200 groups
Voice Broadcast Function
USB Communication Interface

Product Introduction

 

EM1500A Remote Wireless High Voltage Phase Detector also known as satellite timing high-voltage nuclear phaser, has both ultra-long-distance nuclear phase and ordinary short-range nuclear phase functions. It adopts satellite precision timing technology to achieve long-distance nuclear phase, close-range ordinary nuclear phase, basement nuclear phase, and mine nuclear phase. The timing accuracy is less than 20nS, and the joint timing is achieved to ensure the accuracy of the nuclear phase.Ordinary nuclei are 200m apart (in an open place), and satellite nuclei are 5000m apart.This phase detector can perform phase verification both on high-voltage lines and in high-voltage switchgear (central cabinets, ring network cabinets, etc.), and realize functions such as automatic phase verification, phase testing, frequency testing, phase sequence judgment, power verification, and voltage level display from 10V to 500kV voltage level.When the line voltage exceeds 110kV, a non-contact nuclear phase must be used. During the nuclear phase, the metal probe hook of the detector is gradually approached to the wire. When the electric field signal is sensed, the nuclear phase can be completed without direct contact with the high-voltage wire, which is safe and fast.When used for the nuclear phase of the ring network cabinet, the detector must use a probe and a ring network cabinet test line.
EM1500A Remote Wireless High Voltage Phase Detector consists of 2 mainframes, 2 detectors, telescopic insulating rods, monitoring software, etc. The mainframe adopts a 3.5-inch true-color LCD screen, which can display the phase, frequency, phase sequence and nuclear phase results on the same screen. The vector diagram indication and phase indication are clear and intuitive; it has the “X signal is normal, Y signal is normal, in-phase, out-of-phase” voice prompt function, making the test easier and easier.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.

Product Features
1. Two nuclear phase modes: satellite remote nuclear phase mode and short-range ordinary nuclear phase mode.
2. Voice broadcast function, voice prompt: “X signal is normal, Y signal is normal, Z signal is normal, positive phase sequence, inverse phase sequence”.
3. Using a 3.5-inch LCD color screen, the phase, frequency, phase sequence, and nuclear phase results can be displayed on the same screen, and the vector diagram indication and phase indication are clear and intuitive.
4. The instrument has the functions of power inspection and voltage level display.
5. Storage function, 200 sets of data storage.
6. USB communication interface.
7. Rechargeable lithium battery

Technical Parameters

Specification NameParameters Description
Power SupplyHost: 3.7V, 2600mAh rechargeable lithium battery
Detector: 3.7V, 1000mAh rechargeable lithium battery
Display3.5 inch color LCD screen; display area: 71mm x 53mm
Phase Detecting ModeSatellite remote nuclear phase mode, short-range ordinary nuclear phase mode
Phase Detecting Method

When the phase-check voltage is ≤110 kV, contact phase checking may be used.

When the displayed phase-check voltage is between 10 kV and 110 kV, non-contact phase checking may be used (by checking the insulation sheath of the cable).

When the phase-check voltage is >110 kV, non-contact phase checking must be used.

Phase Detecting VoltageAC 10V~500kV
Satellite Phase Detecting Distance5000m
Ordinary Phase Detecting Distance200m
Phase Difference QualitativeIn-phase: -20°~20°; out-of-phase: 100°~140° and 220°~260°
RangeTest phase: 0°~360°
Test frequency: 45.0Hz~65.0Hz
AccuracyPhase: ≤±10°
Frequency: ≤±2Hz
ResolutionPhase: 1° Frequency: 0.1Hz
Electricity Testing Indication“Beep-beep-beep” beep
Voltage Level Display Range0.4kV~110kV
Satellite Timing Accuracy<20nS
Satellite Searching IndicationDynamically display the “—-” symbol when searching for satellites
Satellite Searching TimeThe first star search time is about 2 minutes, the second boot after the star search is successful, the star search time is about 15 seconds, and the subsequent hot start is about 1 second.
No Satellite Continuous TimeAfter the star search is successful, try to continue the nuclear phase until there is no satellite signal, which can last for 1 hour, fully meeting the requirements of the basement nuclear phase and the electric room core.
Automatically Switch Timing ModeAccording to the strength of the satellite signal, the satellite receiving nuclear phase and the timing nuclear phase are automatically switched, without the need to choose whether the satellite mode or the timing mode.
Display Rate2 times/second
Data Storage200 groups (no data will be lost after power-down)
Automatic ShutdownNormal nuclear phase mode is turned on for about 15 minutes without operation and automatically shuts down
Battery VoltageSatellite remote nuclear phase mode is turned on for about 45 minutes without operation and automatically shuts down
Rated CurrentDetector: 30mA max; host: 150mA max
DimensionsHost 195mm x 100mm x 45mm; detector 130mm x 65mm x 45mm
Weight

Host: approx. 415g*2 (including battery);
Detector: approx. 156g*2 (including battery);
Total mass: approx. 7.79kg (including accessories)

Length Of Telescopic Insulating Rod670mm ~ 3000mm
Insulation TestBoth ends of the insulating rod after stretching: AC 220kV/rms
Host, detector: AC 3700V/rms (between exposed metal and plastic shell)
External InterferenceNo extra-strong electromagnetic field; no 433MHz co-frequency interference
Suitable Safety StandardGB13398-92, GB311.1-311.6-8, 3DL408-91 standards and national power industry standards “General technical conditions for 1kV~35kV Portable Nuclear phase Shifters for Live Operation DL/T 971-2017” requirements
Working Temperature & Humidity– 10℃~40℃; below 80%RH
Storage Temperature & Humidity– 10℃~60℃; below 70%RH

Model Comparison

Product ModelPhase Detecting DistancePhase Detecting Voltage

Phase Test

Others

 

EM1050

 

200mAC 10V~500kV0°~360°

Basic Phase Verification

Phase Sequence Test

 

EM1500

 

200mAC 10V~500kV0°~360°Basic Phase Verification

 

EM1500A

 

5000mAC 10V~500kV0°~360°

Basic Phase Verification
Remote Phase Balancing

 

EM1500B

 

500kmAC 10V~500kV0°~360°Basic Phase Verification
Remote Phase Balancing

 

EM1520

 

30mAC 1V~600V0°~360°Basic Phase Verification

 

EM1540

 

20mAC 10kV/35kV0°~360°Basic Phase Verification

 

EM1560A

 

500kmAC 10V~500kV0°~360°Basic Phase Verification
Remote Phase Balancing

 

EM1600

 

60mAC 220V~220kV0°~360°Basic Phase Verification
Exit mobile version