![]() | EM9200 H/L Voltage Clamp Current Meter Product Series : Large Caliber HV/LV Clamp Current Meter Main FeaturesUsed for measurement of H/L voltage AC current of overhead line below 60kV Current Measurement Range: AC 0mA ~ 1200A Clamp Jaw Size: Φ68mm Peak Hold Function Data Storage: 99 groups |
EM9200 H/L Voltage Clamp Current Meteralso known as overhead line load tester, high voltage load tester, high altitude current tester, high voltage current telemeter, which is used for measurement of H/L voltage of overhead line. The meter is composed of dedicated clamp type current meter and high voltage insulation rod. If do not use an insulating rod, it can also be used as high-precision low-voltage clamp ammeter. It is widely used in substation, power plant, industrial and mining enterprise, testing station, electrician maintenance department for current detection and field electrician operation,etc.
The innovative integrated design of EM9200 H/L Voltage Clamp Current Meter clamp jaw and guidance zone can quickly and easily clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe and fast.The meter also has functions such as peak hold, data hold, and memory, etc.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.
Product Features
1.Suitable for line voltage below 60kV, the insulated rod should be required when measure above 600V.
2.Innovative automatic plug-in/out structure, clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe, efficient and fast.
3.Large caliber is suitable for thick cable testing.
4.Can be used to measure leakage current.
5.Peak hold function.
6.Data storage 99 groups.
Technical Parameters
| Specification Name | Parameters Description |
| Power Supply | DC6V alkaline dry battery (1.5V AAA×4) |
| Display Mode | 4-digit LCD display, backlight function, suitable for dim place |
| LCD Size | 35mm × 21.5mm |
| Measurement Method | Clamp CT, integration method |
| Clamp Jaw Size | Φ68mm |
| Measurement Range | AC 0.00mA ~ 600.0A |
| Current Frequency | 50Hz/60Hz automatic |
| Resolution | 1mA |
| Shift Gear | 0mA ~ 1200A Fully automatic shift gear |
| Test Accuracy | 0mA ~ 100A: ±1%rdg±5dgt |
| 100A ~ 599A: ±1.5%rdg±5dgt | |
| 600A ~ 1200A:±2%rdg±5dgt | |
| Data Storage | 99 groups, in storage process “MEM” symbol display, “FULL” symbol flicker indicate storage full |
| PEAK Hold | Automatically hold the test value at high point. Usually Press PEAK key in the test mode ,the PEAK lamp lights up. The peak hold function is enabled, press PEAK key again to cancel this function. |
| Line Voltage | Suitable for testing insulated line below 60kV, as well as bare conductor or busbar below 35kV. (operate with insulating rod) |
| Data Hold | Press HOLD key to hold data in test mode, “HOLD” symbol display, press HOLD key again to cancel this function. |
| Data Access | “MR” symbol display, can look up all storage data |
| Sampling Rate | 2 times/second |
| Overflow Display | Exceed measure range overflow function:”OL A” symbol display |
| Automatic Shutdown | After 15 minutes power on, the meter shuts down automatically without any operation to reduce battery consumption |
| Battery Voltage | When battery voltage is lower than 4.8V, low battery voltage symbol display and remind to replace battery. |
| Meter Dimensions | 135mm × 215mm × 60mm |
| Weight | Meter: approx. 620g (include battery), Receiver: approx. 330g(include battery), Total weight: approx. 4kg(include insulating rod and battery) |
| Interference | No 315MHz, 433MHz same frequency signal interference |
| Telescoping Insulating Rod Size | Approx. 4300mm |
| Insulation Strength | AC 60kV/rms (The telescopic insulating rod is completely pulled apart, between the two ends) |
| Structure | Anti-drip typeⅡ |
| Working Temperature & Humidity | – 20℃ ~ 40℃; below 80%RH |
| Storage Temperature & Humidity | – 20℃ ~ 60℃; below 70%RH |
| EM9200B H/L Voltage Clamp Current Meter Product Series : Large Caliber HV/LV Clamp Current Meter Main FeaturesUsed for measurement of H/L voltage AC current of overhead line below 60kV Current Measurement Range: AC 0mA ~ 1200A Clamp Jaw Size: Φ68mm Wireless Transmission Distance: 30m Data Storage: 99 groups |
EM9200B H/L Voltage Clamp Current Meter also known as overhead line load tester, high voltage load tester, high altitude current tester, high voltage current telemeter, which is used for measurement of H/L voltage of overhead line. The meter is composed of dedicated clamp type current meter and high voltage insulation rod. If do not use an insulating rod, it can also be used as high-precision low-voltage clamp ammeter. It is widely used in substation, power plant, industrial and mining enterprise, testing station, electrician maintenance department for current detection and field electrician operation,etc.
EM9200B H/L Voltage Clamp Current Meter is composed of clamp jaw, receiver and insulating rod, the wireless communication distance between the clamp jaw and receiver is 30m. The innovative integrated design of clamp jaw and guidance zone can quickly and easily clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe and fast.The meter also has functions such as data hold, and memory, etc.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.
Product Features
1.Suitable for line voltage below 60kV, the insulated rod should be required when measure above 600V.
2.Innovative automatic plug-in/out structure, clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe, efficient and fast.
3.Large caliber clamp jaw is suitable for measure thick cable.
4.Can be used to measure leakage current.
5.Wireless communication distance: 30m
6.Data Storage: 99 groups.
Technical Parameters
| Specification Name | Parameters Description |
| Power Supply | DC6V alkaline dry battery (1.5V AAA×4) |
| Display Mode | 4-digit LCD display, backlight function, suitable for dim place |
| LCD Size | LCD of detector: 35mm×21.5mm; LCD of receiver: 47mm×28.5mm |
| Measurement Method | Clamp CT, integration method |
| Transmission Mode | 433MHz wireless transmission |
| Transmission Distance | 30m |
| Clamp Jaw Size | Φ68mm |
| Measurement Range | AC 0.00mA ~ 600.0A |
| Current Frequency | 50Hz/60Hz automatic |
| Resolution | 1mA |
| Shift Gear | 0mA ~ 1200A Fully automatic shift gear |
| Test Accuracy | 0mA ~ 100A: ±1%rdg±5dgt |
| 100A ~ 599A: ±1.5%rdg±5dgt | |
| 600A ~ 1200A: ±2%rdg±5dgt | |
| Data Storage | 99 groups, in storage process “MEM” symbol display, “FULL” symbol flicker indicate storage full |
| Line Voltage | Suitable for circuit testing with insulated skin below 60kV, and bare wire or busbar below 35kV.(Operation with insulating rod) |
| Data Hold | Press HOLD key to hold data in test mode, “HOLD” symbol display, press HOLD key again to cancel this function. |
| Data Access | “MR” symbol display, can look up all storage data |
| Sampling Rate | 2 times/second |
| Overflow Display | Exceed measure range overflow function:”OL A” symbol display |
| No Signal Indication | When the receiver has not received transmit signal, dynamic display “no- -“symbol |
| Automatic Shutdown | After 15 minutes power on, the meter shuts down automatically without any operation to reduce battery consumption |
| Battery Voltage | When battery voltage is lower than 4.8V, low battery voltage symbol display and remind to replace battery. |
| Meter Dimensions | Meter:135mm×215mm×60mm; Receiver: 78mm×165mm×42mm |
| Weight | Meter: approx. 620g (include battery), Receiver: approx. 330g(include battery), Total weight: approx. 4kg(include insulating rod and battery) |
| Interference | No 315MHz, 433MHz same frequency signal interference |
| Telescoping Insulating Rod Size | Approx. 4300mm |
| Insulation Strength | AC 60kV/rms (The telescopic insulating rod is completely pulled apart, between the two ends) |
| Structure | Anti-drip typeⅡ |
| Working Temperature & Humidity | – 20℃ ~ 40℃; below 80%RH |
| Storage Temperature & Humidity | – 20℃ ~ 60℃; below 70%RH |