EM9200 H/L Voltage Clamp Current Meter
Product Series : Large Caliber HV/LV Clamp Current Meter
Main FeaturesUsed for measurement of H/L voltage AC current of overhead line below 60kV
Current Measurement Range: AC 0mA ~ 1200A
Clamp Jaw Size: Φ68mm
Peak Hold Function
Data Storage: 99 groups

EM9200 H/L Voltage Clamp Current Meteralso known as overhead line load tester, high voltage load tester, high altitude current tester, high voltage current telemeter, which is used for measurement of H/L voltage of overhead line. The meter is composed of dedicated clamp type current meter and high voltage insulation rod. If do not use an insulating rod, it can also be used as high-precision low-voltage clamp ammeter. It is widely used in substation, power plant, industrial and mining enterprise, testing station, electrician maintenance department for current detection and field electrician operation,etc.
The innovative integrated design of EM9200 H/L Voltage Clamp Current Meter clamp jaw and guidance zone can quickly and easily clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe and fast.The meter also has functions such as peak hold, data hold, and memory, etc.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.


Product Features
1.Suitable for line voltage below 60kV, the insulated rod should be required when measure above 600V.
2.Innovative automatic plug-in/out structure, clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe, efficient and fast.
3.Large caliber is suitable for thick cable testing.
4.Can be used to measure leakage current.
5.Peak hold function.
6.Data storage 99 groups.
EM9200 (6).jpg EM9200 (7).jpg

Technical Parameters

Specification NameParameters Description
Power SupplyDC6V alkaline dry battery (1.5V AAA×4)
Display Mode4-digit LCD display, backlight function, suitable for dim place
LCD Size35mm × 21.5mm
Measurement MethodClamp CT, integration method
Clamp Jaw SizeΦ68mm
Measurement RangeAC 0.00mA ~ 600.0A
Current Frequency50Hz/60Hz automatic
Resolution1mA
Shift Gear0mA ~ 1200A Fully automatic shift gear
Test Accuracy0mA ~ 100A:  ±1%rdg±5dgt  
100A ~ 599A: ±1.5%rdg±5dgt  
600A ~ 1200A:±2%rdg±5dgt
Data Storage99 groups, in storage process “MEM” symbol display, “FULL” symbol flicker indicate storage full
PEAK HoldAutomatically hold the test value at high point. Usually Press PEAK key in the test mode ,the PEAK lamp lights up. The peak hold function is enabled, press PEAK key again to cancel this function.
Line VoltageSuitable for testing insulated line below 60kV, as well as bare conductor or busbar below 35kV. (operate with insulating rod)
Data HoldPress HOLD key to hold data in test mode, “HOLD” symbol display, press HOLD key again to cancel this function.
Data Access“MR” symbol display, can look up all storage data
Sampling Rate2 times/second
Overflow DisplayExceed measure range overflow function:”OL A” symbol display
Automatic ShutdownAfter 15 minutes power on, the meter shuts down automatically without any operation to reduce battery consumption
Battery VoltageWhen battery voltage is lower than 4.8V, low battery voltage symbol display and remind to replace battery.
Meter Dimensions135mm × 215mm × 60mm
WeightMeter: approx. 620g (include battery), Receiver: approx. 330g(include battery), Total weight: approx. 4kg(include insulating rod and battery)
InterferenceNo 315MHz, 433MHz same frequency signal interference
Telescoping Insulating Rod SizeApprox. 4300mm
Insulation StrengthAC 60kV/rms (The telescopic insulating rod is completely pulled apart, between the two ends)
StructureAnti-drip typeⅡ
Working Temperature & Humidity– 20℃ ~ 40℃; below 80%RH
Storage Temperature & Humidity– 20℃ ~ 60℃; below 70%RH
EM9200B H/L Voltage Clamp Current Meter
Product Series : Large Caliber HV/LV Clamp Current Meter
Main FeaturesUsed for measurement of H/L voltage AC current of overhead line below 60kV
Current Measurement Range: AC 0mA ~ 1200A
Clamp Jaw Size: Φ68mm
Wireless Transmission Distance: 30m
Data Storage: 99 groups

EM9200B H/L Voltage Clamp Current Meter also known as overhead line load tester, high voltage load tester, high altitude current tester, high voltage current telemeter, which is used for measurement of H/L voltage of overhead line. The meter is composed of dedicated clamp type current meter and high voltage insulation rod. If do not use an insulating rod, it can also be used as high-precision low-voltage clamp ammeter. It is widely used in substation, power plant, industrial and mining enterprise, testing station, electrician maintenance department for current detection and field electrician operation,etc.
EM9200B H/L Voltage Clamp Current Meter is composed of clamp jaw, receiver and insulating rod, the wireless communication distance between the clamp jaw and receiver is 30m. The innovative integrated design of clamp jaw and guidance zone can quickly and easily clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe and fast.The meter also has functions such as data hold, and memory, etc.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.

Product Features
1.Suitable for line voltage below 60kV, the insulated rod should be required when measure above 600V.
2.Innovative automatic plug-in/out structure, clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe, efficient and fast.
3.Large caliber clamp jaw is suitable for measure thick cable.
4.Can be used to measure leakage current.
5.Wireless communication distance: 30m
6.Data Storage: 99 groups.
EM9200B (6).jpg EM9200B (7).jpg

Technical Parameters

Specification NameParameters Description
Power SupplyDC6V alkaline dry battery (1.5V AAA×4)
Display Mode4-digit LCD display, backlight function, suitable for dim place
LCD SizeLCD of detector: 35mm×21.5mm; LCD of receiver: 47mm×28.5mm
Measurement MethodClamp CT, integration method
Transmission Mode433MHz wireless transmission
Transmission Distance30m
Clamp Jaw SizeΦ68mm
Measurement RangeAC 0.00mA ~ 600.0A
Current Frequency50Hz/60Hz automatic
Resolution1mA
Shift Gear0mA ~ 1200A Fully automatic shift gear
Test Accuracy0mA ~ 100A: ±1%rdg±5dgt  
100A ~ 599A: ±1.5%rdg±5dgt  
600A ~ 1200A: ±2%rdg±5dgt
Data Storage99 groups, in storage process “MEM” symbol display, “FULL” symbol flicker indicate storage full
Line VoltageSuitable for circuit testing with insulated skin below 60kV, and bare wire or busbar below 35kV.(Operation with insulating rod)
Data HoldPress HOLD key to hold data in test mode, “HOLD” symbol display, press HOLD key again to cancel this function.
Data Access“MR” symbol display, can look up all storage data
Sampling Rate2 times/second
Overflow DisplayExceed measure range overflow function:”OL A” symbol display
No Signal IndicationWhen the receiver has not received transmit signal, dynamic display “no- -“symbol
Automatic ShutdownAfter 15 minutes power on, the meter shuts down automatically without any operation to reduce battery consumption
Battery VoltageWhen battery voltage is lower than 4.8V, low battery voltage symbol display and remind to replace battery.
Meter DimensionsMeter:135mm×215mm×60mm; Receiver: 78mm×165mm×42mm
WeightMeter: approx. 620g (include battery),
Receiver: approx. 330g(include battery),
Total weight: approx. 4kg(include insulating rod and battery)
InterferenceNo 315MHz, 433MHz same frequency signal interference
Telescoping Insulating Rod SizeApprox. 4300mm
Insulation StrengthAC 60kV/rms (The telescopic insulating rod is completely pulled apart, between the two ends)
StructureAnti-drip typeⅡ
Working Temperature & Humidity– 20℃ ~ 40℃; below 80%RH