EM2800 Series Type Earth Resistance Online Detector
EM2800B Non-Contact Type Earth Resistance Online Detector
Product Series : Non-Contact Type Earth Resistance Online Detector
Main FeaturesOnline monitoring of the earth resistance, earth current, metal loop connection resistance and grounding down lead connection condition.
Detector Structure: Closed & Integrated type
Sensor Open Jaw Size: 56mm × 27mm
Working Power Supply: 9V DC~24V DC(external power supply)
LCD Display: 47mm × 28.5mm
Earth Resistance Range: 0.01Ω ~ 200Ω
Earth Current Range: 0.0mA~20A
RS485 Communication: Supports MODBUS-RTU communication protocol
4G Communication: Supports MQTT protocol (optional)
Explosion-proof Marking: Exia â…¡BT3Ga
Product Introduction
Â
EM2800B Non-Contact Earth Resistance Online Detector is used for online monitoring of earth resistance, connection status of gounding down lead, loop earth resistance, metal loop connection resistance, and earth current. It is also known as earth resistance online tester and loop resistance online monitor. The tester adopts non-contact measurement technology with the earth wire passing through the sensor, which never affects the lightning protection grounding effect and normal operation of ftesters. The tester has multiple structures to suit different application sites, with IP65 protection level, and supports outdoor installation and use. It is widely applied to transmission line tower grounding, meteorological lightning protection grounding, petrochemical grounding, communication grounding, substation grounding, railway facility grounding, building and warehouse grounding, metal loop resistance value, electrical equipment grounding, etc.
EM2800BÂ Non-Contact Earth Resistance Online Detector consists of sensor, controller, mounting hardware, etc. The sensor has closed-loop and open-loop types to adapt to different application environments. The open-loop structure enables installation without disconnecting the gounding down lines, ensuring convenient and fast operation. The detector can be installed and used individually or built into a network system.
The detector is equipped with RS485 communication (supports MODBUS-RTU communication protocol) or optional 4G communication (supports MQTT communication protocol). An upper computer network monitoring system or 4G network monitoring system can be established via the EM2600 low-power data acquisition tester. Users can use our company’s EM2800-MT IoT earth resistance online monitoring system software to realize real-time monitor and record parameters such as earth resistance values, alarm threshold set, and alarm information view. The background supports account management, information management, area management, equipment management and other functions.
The detector can be powered externally or optional EM2600 low-power data acquisition teter. The data acquisition teter adopts a low-power design with a built-in large-capacity lithium thionyl chloride battery to solves the problem of on-site power supply, and the battery life of up to 3 ~ 5 years.
The non-contact detector has passed explosion-proof certification, and its safety explosion-proof certification parameters meet the relevant requirements of GB3836.1-2021 and GB3836.4-2021 standards. Its explosion-proof marks are Ex ia IIB T3 Ga and Ex ib IIC T4 Gb, with explosion-proof certificate numbers CE23.3868X and EETI25.0421X. It can be applied to corresponding flammable and explosive environments.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.
Product Features
1. The detector has multiple structures to suit various application scenarios.
2. Closed & Integrated type detector with low cost, requiring disconnection of the gounding down line during installation.
3. Multi-function Wide Range: Earth resistance range: 0.01Ω ~ 200Ω; Earth current range: 0.0mA ~ 20A.
4. Multiple Cmmunication Methods: RS485 communication and 4G communication
5. With self-checking function, which enables remote detection whether the detector is working properly via protocol.
6. With line resistance elimination function, which can reduce the influence of line resistance on measurement errors.
7. Lightning Protection Function: suitable for outdoor environments with frequent lightning strikes.
8. Alarm Function: Supports alarm threshold setting with audible and visual alarm indication.
9. Passed explosion-proof certification with explosion-proof marks Ex ia IIB T3 Ga and Ex ib IIC T4 Gb.
10.Configurable with low-power data acquisition test, integrating RS485, LoRa, 4G and other communication interfaces for centralized collection of on-site equipment, with built-in lithium battery and battery life of more than 3 years.
Â
Â
 
Product Installation Gallery
Network Configuration Diagram
 
Technical Parameters
| Specification Name | Parameters Description |
| Functions | Online monitoring of loop earth resistance, metal loop connection resistance, grounding condition, and earth current |
| Power Supply | 9V DC ~ 24V DC (User external power supply or equipped with a low-power communication module) |
| Display | 4-digit LCD, 47mm × 28.5mm (optional) |
| Power Supply Mode | Externally supplied power. When use in dangerous locations, power must be connected to the detector via a DC signal input isolated safety barrier, with the safety barrier installed in a non-dangerous area. |
| Earth Resistance Measurement | Range: 0.01Ω ~ 200Ω; Resolution: 0.001Ω; Accuracy: ±2%rdg ±3dgt |
| Earth Current Measurement | Range: AC 0.0mA ~ 20A; Resolution: 0.1mA; Accuracy: ±2%rdg ±5dgt |
| Sensor Open Jaw Size | 56mm × 27mm |
| Shift | Fully automatic shifting |
| Overrange Indication | When resistance > 200Ω; current > 20A, “OL” displayed. |
| Power & Communication Wire Identification | Red: Power input positive ; |
| Uploaded Data | Earth resistance value, earth current value, alarm threshold |
| Network Points | Wired network: 1 ~ 250 grounding points, expandable |
| Communication Distance | Wired network: Approx. 1000m, expandable |
| Alarm Indication | Audible & visual alarm |
| Alarm Setting | Background setting |
| Ground Wire Interference Current | Avoide |
| External Magnetic Field | < 40A/m |
| External Electric Field | < 1V/m |
| Single Measurement Time | Approx. 0.5s |
| Working Current | 12VDC 50mA Max (4G version: 12VDC 150mA Max) |
| Explosion-Proof Mark | Ex ia â…¡B T3 Ga, Ex ib â…¡C T4 Gb |
| Explosion-Proof Certificate Number | CE23.3868X, EETI25.0421X |
| Protection Level | IP65 |
| RS485 Communication | Supports ModBus protocol |
| 4G Communication Module (Optional) | Supports MQTT protocol |
| Dimensions | 119mm × 108mm × 124mm |
| Weight | Approx. 870g |
| Working Temperature & Humidity | – 20℃ ~ 55℃; 20%RH ~ 90%RH |