EM1050/EM1500/EM1600/EM1500A/EM1500B/EM1560A Wireless HV/LV Remote Phase Detector
EM1500A Remote Wireless High Voltage Phase Detector
Product Series : Wireless HV/LV Remote Phase Detector
Main Features :
Used for remote nuclear phase, phase test, frequency test, phase sequence judgment and power inspection of power lines, high-voltage switchgear or substations below 500kV
Nuclear Phase Voltage: 10V~500kV
Remote core-to-core Distance: 5000m
Ordinary core-to-core Distance: 200m
Phase Range: 0°~360°
Frequency Range: 45.0Hz~65.0Hz
Voltage Level Display Range:0.4kV ~ 110kV
Length Of Telescopic Insulating Rod:670mm ~ 3000mm
Date Storages: 200 groups
Voice Broadcast Function
USB Communication Interface
Product Introduction
EM1500A Remote Wireless High Voltage Phase Detector also known as satellite timing high-voltage nuclear phaser, has both ultra-long-distance nuclear phase and ordinary short-range nuclear phase functions. It adopts satellite precision timing technology to achieve long-distance nuclear phase, close-range ordinary nuclear phase, basement nuclear phase, and mine nuclear phase. The timing accuracy is less than 20nS, and the joint timing is achieved to ensure the accuracy of the nuclear phase.Ordinary nuclei are 200m apart (in an open place), and satellite nuclei are 5000m apart.This phase detector can perform phase verification both on high-voltage lines and in high-voltage switchgear (central cabinets, ring network cabinets, etc.), and realize functions such as automatic phase verification, phase testing, frequency testing, phase sequence judgment, power verification, and voltage level display from 10V to 500kV voltage level.When the line voltage exceeds 110kV, a non-contact nuclear phase must be used. During the nuclear phase, the metal probe hook of the detector is gradually approached to the wire. When the electric field signal is sensed, the nuclear phase can be completed without direct contact with the high-voltage wire, which is safe and fast.When used for the nuclear phase of the ring network cabinet, the detector must use a probe and a ring network cabinet test line.
EM1500A Remote Wireless High Voltage Phase Detector consists of 2 mainframes, 2 detectors, telescopic insulating rods, monitoring software, etc. The mainframe adopts a 3.5-inch true-color LCD screen, which can display the phase, frequency, phase sequence and nuclear phase results on the same screen. The vector diagram indication and phase indication are clear and intuitive; it has the “X signal is normal, Y signal is normal, in-phase, out-of-phase” voice prompt function, making the test easier and easier.
ETCRMETER is a high-end brand of ETCR. All products are manufactured by ETCR, which also provides technical support and after-sales service.
Product Features
1. Two nuclear phase modes: satellite remote nuclear phase mode and short-range ordinary nuclear phase mode.
2. Voice broadcast function, voice prompt: “X signal is normal, Y signal is normal, Z signal is normal, positive phase sequence, inverse phase sequence”.
3. Using a 3.5-inch LCD color screen, the phase, frequency, phase sequence, and nuclear phase results can be displayed on the same screen, and the vector diagram indication and phase indication are clear and intuitive.
4. The instrument has the functions of power inspection and voltage level display.
5. Storage function, 200 sets of data storage.
6. USB communication interface.
7. Rechargeable lithium battery
Technical Parameters
| Specification Name | Parameters Description |
| Power Supply | Host: 3.7V, 2600mAh rechargeable lithium battery Detector: 3.7V, 1000mAh rechargeable lithium battery |
| Display | 3.5 inch color LCD screen; display area: 71mm x 53mm |
| Phase Detecting Mode | Satellite remote nuclear phase mode, short-range ordinary nuclear phase mode |
| Phase Detecting Method | When the phase-check voltage is ≤110 kV, contact phase checking may be used. When the displayed phase-check voltage is between 10 kV and 110 kV, non-contact phase checking may be used (by checking the insulation sheath of the cable). When the phase-check voltage is >110 kV, non-contact phase checking must be used. |
| Phase Detecting Voltage | AC 10V~500kV |
| Satellite Phase Detecting Distance | 5000m |
| Ordinary Phase Detecting Distance | 200m |
| Phase Difference Qualitative | In-phase: -20°~20°; out-of-phase: 100°~140° and 220°~260° |
| Range | Test phase: 0°~360° |
| Test frequency: 45.0Hz~65.0Hz | |
| Accuracy | Phase: ≤±10° |
| Frequency: ≤±2Hz | |
| Resolution | Phase: 1° Frequency: 0.1Hz |
| Electricity Testing Indication | “Beep-beep-beep” beep |
| Voltage Level Display Range | 0.4kV~110kV |
| Satellite Timing Accuracy | <20nS |
| Satellite Searching Indication | Dynamically display the “—-” symbol when searching for satellites |
| Satellite Searching Time | The first star search time is about 2 minutes, the second boot after the star search is successful, the star search time is about 15 seconds, and the subsequent hot start is about 1 second. |
| No Satellite Continuous Time | After the star search is successful, try to continue the nuclear phase until there is no satellite signal, which can last for 1 hour, fully meeting the requirements of the basement nuclear phase and the electric room core. |
| Automatically Switch Timing Mode | According to the strength of the satellite signal, the satellite receiving nuclear phase and the timing nuclear phase are automatically switched, without the need to choose whether the satellite mode or the timing mode. |
| Display Rate | 2 times/second |
| Data Storage | 200 groups (no data will be lost after power-down) |
| Automatic Shutdown | Normal nuclear phase mode is turned on for about 15 minutes without operation and automatically shuts down |
| Battery Voltage | Satellite remote nuclear phase mode is turned on for about 45 minutes without operation and automatically shuts down |
| Rated Current | Detector: 30mA max; host: 150mA max |
| Dimensions | Host 195mm x 100mm x 45mm; detector 130mm x 65mm x 45mm |
| Weight | Host: approx. 415g*2 (including battery); |
| Length Of Telescopic Insulating Rod | 670mm ~ 3000mm |
| Insulation Test | Both ends of the insulating rod after stretching: AC 220kV/rms Host, detector: AC 3700V/rms (between exposed metal and plastic shell) |
| External Interference | No extra-strong electromagnetic field; no 433MHz co-frequency interference |
| Suitable Safety Standard | GB13398-92, GB311.1-311.6-8, 3DL408-91 standards and national power industry standards “General technical conditions for 1kV~35kV Portable Nuclear phase Shifters for Live Operation DL/T 971-2017” requirements |
| Working Temperature & Humidity | – 10℃~40℃; below 80%RH |
| Storage Temperature & Humidity | – 10℃~60℃; below 70%RH |
Model Comparison
| Product Model | Phase Detecting Distance | Phase Detecting Voltage | Phase Test | Others |
| 200m | AC 10V~500kV | 0°~360° | Basic Phase Verification Phase Sequence Test |
| 200m | AC 10V~500kV | 0°~360° | Basic Phase Verification |
| 5000m | AC 10V~500kV | 0°~360° | Basic Phase Verification |
| 500km | AC 10V~500kV | 0°~360° | Basic Phase Verification Remote Phase Balancing |
| 30m | AC 1V~600V | 0°~360° | Basic Phase Verification |
| 20m | AC 10kV/35kV | 0°~360° | Basic Phase Verification |
| 500km | AC 10V~500kV | 0°~360° | Basic Phase Verification Remote Phase Balancing |
| 60m | AC 220V~220kV | 0°~360° | Basic Phase Verification |